We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on
Spec Detail
Servo amplifier model MR-JE- | 10B | 20B | 40B | 70B | 100B | 200B | 300B | |
Output | Rated voltage | 3-phase 170 V AC | ||||||
Rated current[A] | 1.1 | 1.5 | 2.8 | 5.8 | 6.0 | 11.0 | 11.0 | |
Power supply input | Voltage/frequency (Note 1) | 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz | 3-phase or 1-phase 200 V AC to 240 V AC, 50 Hz/60 Hz (Note 8) | 3-phase 200 V AC to 240 V AC, 50 Hz/60 Hz | ||||
Rated current (Note 7)[A] | 0.9 | 1.5 | 2.6 | 3.8 | 5.0 | 10.5 | 14.0 | |
Permissible voltage fluctuation | 3-phase or 1-phase 170 V AC to 264 V AC | 3-phase or 1-phase 170 V AC to 264 V AC (Note 8) | 3-phase 170 V AC to 264 V AC | |||||
Permissible frequency fluctuation | ±5% maximum | |||||||
Interface power supply | 24 V DC ± 10% (required current capacity: 0.1 A) | |||||||
Control method | Sine-wave PWM control/current control method | |||||||
Tolerable regenerative power of the built-in regenerative resistor (Note 2, 3)[W] | - | - | 10 | 20 | 20 | 100 | 100 | |
Dynamic brake | Built-in (Note 4) | |||||||
SSCNET III/H command communication cycle (Note 6) |
0.444 ms, 0.888 ms | |||||||
Communication function | USB: Connect a personal computer (MR Configurator2 compatible) | |||||||
Servo function | Advanced vibration suppression control II, adaptive filter II, robust filter, auto tuning, one-touch tuning, tough drive function, drive recorder function, tightening & press-fit function, machine diagnosis function, power monitoring function, lost motion compensation function | |||||||
Protective functions | Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheat protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, error excessive protection, hotline forced stop function (Note 9) | |||||||
Compliance to global standards | Refer to "Conformity with global standards and regulations" in the catalog. | |||||||
Structure (IP rating) | Natural cooling, open (IP20) | Force cooling, open (IP20) | ||||||
Close mounting (Note 5) | 3-phase power supply input | Possible | ||||||
1-phase power supply input | Possible | Not possible | - | |||||
Environment | Ambient temperature | Operation: 0 ℃ to 55 ℃ (non-freezing), storage: -20 ℃ to 65 ℃ (non-freezing) | ||||||
Ambient humidity | Operation/Storage: 90 %RH maximum (non-condensing) | |||||||
Ambience | Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust | |||||||
Altitude | 1000 m or less above sea level | |||||||
Vibration resistance | 5.9 m/s2 at 10 Hz to 55 Hz (directions of X, Y and Z axes) | |||||||
Mass[kg] | 0.8 | 0.8 | 0.8 | 1.5 | 1.5 | 2.1 | 2.1 |
About Mitsubishi Servo Driver:
1. Rated output and speed of a servo motor are applicable when the servo amplifier, combined with the servo motor, is operated within the specified power supply voltage and frequency.
2. Select the most suitable regenerative option for your system with our capacity selection software.
3. Refer to "Regenerative Option" in the catalog for the tolerable regenerative power [W] when regenerative option is used.
4. When using the built-in dynamic brake, refer to "MR-JE-_B Servo Amplifier Instruction Manual" for the permissible load to motor inertia ratio.
5. When the servo amplifiers are closely mounted, keep the ambient temperature within 0 ℃ to 45 ℃, or use them with 75% or less of the effective load ratio.
6. The command communication cycle depends on the controller specifications and the number of axes connected.
7. This value is applicable when a 3-phase power supply is used.
8. When a 1-phase 200 V AC to 240 V AC power supply is used, use the servo amplifiers with 75% or less of the effective load ratio.
9. When an alarm occurs on MR-JE-B servo amplifier, the hot line forced stop signal will be sent to other servo amplifiers through a controller, and all the servo motors that are operated normally by MR-JE-B servo amplifiers decelerate to a stop. Refer to "MR-JE-_B Servo Amplifier Instruction Manual" for details.
-Solutions Of Servo Driver Mitsubishi:
(1) Irrigation
The delivery of water is a complex challenge involving tremendous distances from water source to agricultural end-users. Mitsubishi Electric's technologies provide automation solutions that deliver water where and when it is needed in the correct quantities, with minimal loss.
Downstream Productivity and Efficiency
In large-scale agriculture, automation can have a huge impact on conserving water, energy and labor. Our irrigation control solutions enable automatic monitoring and control of remote valves in ideal night conditions, saving water, energy and valuable man-hours.
Synergy of Solutions
Mitsubishi Electric offers one-stop automation solutions. Through the right combination of our proprietary technologies, we can craft the ideal solution for any irrigation project of any scale, from automating the control of rivers to optimal irrigation of a vineyard.
(2)Local Automation
Local automation stations for different process units are widely used in the SCADA systems of the oil and gas industry, but the local stations, with limited number of I/O channels, are often located hundreds of kilometers away from the central control room.
Mitsubishi Electric offers an extensive lineup of equipment to provide the ideal local automation solution for a variety of needs. For example, our compact PLC for systems with limited signal scoring helps reduce system costs. We also offer highly reliable communications equipment optimized for remote monitoring.
Major Applications of Our Products:
- Gas and oil well sites
- Test separators
- Chemical injection skids
- Water intake facilities and reservoir pressure maintenance systems
- Pump and compressor stations
- Transformer substations
- Independent boiler facilities
- Controlled facilities for pipeline telemetry
- Cathode protection stations for pipelines