Omron Hot sale PLC module CPU module unit CJ1M-CPU13-ETN

Short Description:

• Compact 90 × 65 mm (H × D) dimensions are first class in the industry.

• SYSMAC CJ-series CPU Unit with the functionality of an Ethernet Unit.

• The CPU functional element has the same functionality as a CJ1M-CPU11/12/13. The enables effective usage of legacy applications.


  • FOB Price: US $0.5 - 9,999 / Piece
  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on

    Product Detail

    Product Tags

    Sichuan Focus Technology Co., Ltd.

    We have more than 10 years of experience in products used in the field of industrial automation! We mainly focus on industrial automation products, such as servo motor, PLC, HMI,Variable-frequency Drive, circuit breakers, contactors, surgeprotector, thermostat, encoder, relays,and IGBT! Our automation products have been exported to more than 50 countries and regions!

    We have our own brand focus, and also have close and long-term cooperation with other well-known brands! Because of our high quality, competitive price and fast delivery, we have helped most of our customers succeedin their market! We will constantly improve ourselves to meet more requirements of customers!

    Spec Detail

    Item Specifications
    Control method Stored program
    I/O control method Cyclic scan and immediate processing are both possible.
    Programming Languages Ladder Logic (LD), Sequential Function Charts (SFC), Structured Text (ST), and
    Mnemonic.
    CPU processing mode Normal Mode or Peripheral Servicing Priority Mode
    Instruction length 1 to 7 steps per instruction
    Ladder instructions Approx. 400 (3-digit function codes)
    Execution
    time
    Basic instructions 0.10 μs min.
    Special
    instructions
    0.15 μs min.
    Overhead time CJ1M-CPU12-ETN/CPU13-ETN: 0.5 ms min.
    CJ1M-CPU11-ETN: 0.7 ms min.
    Unit connection method No Backplane: Units connected directly to each other.
    Mounting method DIN Track (screw mounting not possible)
    Maximum number of
    connectable Units
    Total of 19 Units, including 9 Units on CPU Rack and 10 Units on one Expansion
    Rack.
    (The built-in Ethernet port on the CPU Unit must be allocated to a slots 0, and is
    counted as one Unit.)
    Maximum number of Expansion
    Racks
    CJ1M-CPU13-ETN: 1 max. (An I/O Control Unit is required on the CPU Rack and
    an I/O Interface Unit is required on the Expansion Rack.)
    CJ1M-CPU11-ETN/12-ETN: Expansion is not possible.
    Number of tasks 288 (cyclic tasks: 32, interrupt tasks: 256)
    With CJ1-H or CJ1M CPU Units, interrupt tasks can be defined as cyclic tasks
    called extra cyclic tasks. Including these, up to 288 cyclic tasks can be used.
    Cyclic tasks are executed each cycle and are controlled with TKON (820) and
    TKOF (821) instructions.
    Note 1.
    The following 4 types of interrupt tasks are supported.
    Note 2.
    Power OFF interrupt tasks: 1 max.
    Scheduled interrupt tasks: 2 max.
    I/O interrupt tasks: 32 max.
    External interrupt tasks: 256 max.
    Interrupt types Scheduled Interrupts: Interrupts generated at a time scheduled by the CPU Units
    built-in timer.
    I/O Interrupts: Interrupts from Interrupt Input Units.
    Power OFF Interrupts (See note): Interrupts executed when the CPU Units power
    is turned OFF.
    External I/O Interrupts: Interrupts from the Special I/O Units or CPU Bus Units.
    Note: Not supported when the CJ1W-PD022 Power Supply Unit is mounted.
    Calling subroutines from more
    than one task
    Supported (called global subroutines).
    CIO
    (Core I/O)
    Area
    I/O Area 2,560: CIO 000000 to CIO 015915 (160 words from CIO 0000 to
    CIO 0159)
    The setting of the first word can be changed from the default (CIO
    0000) so that CIO 0000 to CIO 0999 can be used.
    I/O bits are allocated to Basic I/O Units.
    The CIO Area
    can be used
    as work bits
    if the bits are
    not used as
    shown here.
    Link Area 3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to
    CIO 1199)
    Link bits are used for data links and are allocated to Units in
    Controller Link Systems.
    CPU Bus Unit Area 6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to
    CIO 1899)
    CPU Bus Unit bits store the operating status of CPU Bus Units.
    (25 words per Unit, 16 Units max.)
    Special I/O Unit
    Area
    15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000
    to CIO 2959)
    Special I/O Unit bits are allocated to Special I/O Units. (10 words
    per Unit, 96 Units max.)
    Serial PLC Link
    Area (CJ1M CPU
    Units only)
    1,440 (90 words): CIO 310000 to CIO 318915 (words CIO 3100 to
    CIO 3189)
    DeviceNet Area 9,600 (600 words): CIO 320000 to CIO 379915 (words CIO 3200 to
    CIO 3799)
    DeviceNet bits are allocated to Slaves for DeviceNet Unit remote
    I/O communications when the Master function is used with fixed
    allocations.
    Fixed allocation setting 1 Outputs: CIO 3200 to CIO 3263
    Inputs: CIO 3300 to CIO 3363
    Fixed allocation setting 2 Outputs: CIO 3400 to CIO 3463
    Inputs: CIO 3500 to CIO 3563
    Fixed allocation setting 3 Outputs: CIO 3600 to CIO 3663
    Inputs: CIO 3700 to CIO 3763
    The following words are allocated to the Master function even
    when the DeviceNet Unit is used as a Slave.
    Fixed allocation setting 1 Outputs: CIO 3370 (Slave to Master)
    Inputs: CIO 3270 (Master to Slave)
    Fixed allocation setting 2 Outputs: CIO 3570 (Slave to Master)
    Inputs: CIO 3470 (Master to Slave)
    Fixed allocation setting 3 Outputs: CIO 3770 (Slave to Master)
    Inputs: CIO 3670 (Master to Slave)
    Internal I/O Area 4,800 bits (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)
    37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 CIO 6143)
    These bits in the CIO Area are used as work bits in programming to control
    program execution. They cannot be used for external I/O.
    Work Area 8,192 bits (512 words): W00000 to W51115 (W000 to W511)
    Controls the programs only. (I/O from external I/O terminals is not possible.)
    Note: When using work bits in programming, use the bits in the Work Area first
    before using bits from other areas.
    Holding Area 8,192 bits (512 words): H00000 to H51115 (H000 to H511) Holding bits are used to
    control the execution of the program, and maintain their ON/OFF status when the
    PLC is turned OFF or the operating mode is changed.
    Note: The Function Block Holding Area words are allocated from H512 to H1535.
    These words can be used only for the function block instance area (internally
    allocated variable area).
    Auxiliary Area Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)
    Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)
    Auxiliary bits are allocated specific functions.
    Temporary Area 16 bits (TR0 to TR15)
    Temporary bits are used to temporarily store the ON/OFF execution conditions at
    program branches.
    Timer Area 4,096: T0000 to T4095 (used for timers only)
    Counter Area 4,096: C0000 to C4095 (used for counters only)
    DM Area 32 Kwords: D00000 to D32767
    Used as a general-purpose data area for reading and writing data in word units (16
    bits). Words in the DM Area maintain their status when the PLC is turned OFF or
    the operating mode is changed.
    Internal Special I/O Unit DM Area: D20000 to D29599 (100 words × 96 Units)
    Used to set parameters for Special I/O Units.
    CPU Bus Unit DM Area: D30000 to D31599 (100 words × 16 Units)
    Used to set parameters for CPU Bus Units.
    EM Area None
    Index Registers IR0 to IR15
    Store PLC memory addresses for indirect addressing. Index registers can be used
    independently in each task.
    One register is 32 bits (2 words).
    Setting to use index registers either independently in each task or to share them
    between tasks.
    Task Flag Area 32 (TK0000 to TK0031)
    Task Flags are read-only flags that are ON when the corresponding cyclic task is
    executable and OFF when the corresponding task is not executable or in standby
    status.
    Trace Memory 4,000 words (trace data: 31 bits, 6 words)
    File Memory Memory Cards: Compact flash memory cards can be used (MS-DOS format).
    OMRON Memory Cards can be used.

  • Previous: