New Original CJIW D/A Module PLC Controller Module CJ1W-DA041

Short Description:

Analog output unit, 2 x outputs 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA, externally powered 24 VDC 140mA, screw terminal

 


We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on

Product Detail

Product Tags

CJ1W-AD041-V1/081-V1/AD042
CJ1W-DA021/041/08V/08C/DA042V
CJ1W-MAD42

CJ1W-AD / DA / MAD Dimensions 1
Item CJ1W-DA021 CJ1W-DA041 CJ1W-DA08V CJ1W-DA08C CJ1W-DA042V
Unit type CJ-series Special I/O Unit
Isolation *1 Between I/O and Controller signals:
Photocoupler (No isolation between I/O signals.)
Between I/O and
Controller signals:
Digital isolator (No
isolation between
I/O signals.)
External terminals 18-point detachable terminal block (M3 screws)
Power consumption 5 VDC, 120 mA max. 5 VDC, 140 mA max. 5 VDC, 400 mA max.
External power supply *2 24 VDC +10% -15%,
(inrush current: 20 A max., pulse width: 1 ms min.)
140 mA max. 200 mA max. 140 mA max. 170 mA max.
Dimensions (mm) 31 × 90 × 65 mm (W × H × D)
Weight 150 g max.
General specifications Conforms to general specifications for CJ-series Series.
Output
specifi-
cations
Number of analog outputs 2 4 8 8 4
Output signal range *3 1 to 5 V/4 to 20 mA
0 to 5 V
0 to 10 V
- 10 to 10 V
1 to 5 V
0 to 5 V
0 to 10 V
- 10 to 10 V
4 to 20 mA 1 to 5 V
0 to 10 V
- 10 to 10 V
Output impedance 0.5 Ω max. (for voltage output) 0.5 Ω max. (for
voltage output)
0.5 Ω max.
(for voltage output)
Max. output current (for
1 point)
12 mA (for voltage output) 2.4 mA (for
voltage output)
2 mA
(for voltage output)
Maximum permissible
load resistance
600 Ω (current output) 350 Ω
Resolution 40,000 4,000/8,000 *8 1 to 5 V 10,000
0 to 10 V 20,000
-10 to 10 V 40,000
Set data 16-bit binary data
Accuracy
*4
25 °C Voltage output: ± 0.3% of F.S.
Current output: ± 0.5% of F.S.
± 0.3% of F.S. ± 0.3% of F.S. ± 0.3% of F.S.
0 °C to 55 °C Voltage output: ± 0.5% of F.S.
Current output: ± 0.8% of F.S.
± 0.5% of F.S. ± 0.6% of F.S. ± 0.5% of F.S.
D/A conversion period *5 1.0 ms per point 1.0 ms or 250 μs per point *8 20 μs/1 point,
25 μs/2 points,
30 μs/3 points,
35 μs/4 points
Output
functions
Output hold function Outputs the specified output status (CLR, HOLD, or MAX) under any of the following
circumstances.
When the Conversion Enable Bit is OFF. *6
In adjustment mode, when a value other than the output number is output during adjustment. *7
When output setting value error occurs or Controller operation stops.
When the Load is OFF.
Scaling Supported only for a conversion
period of 1 ms and resolution of
4,000.
Setting values in any specified
unit within a range of ± 32,000
as the upper and lower limits
allows D/A conversion to be
executed and analog signals to
be output with these values as
full scale.
Setting values in any
specified unit within a
range of ±32,000 as the
upper and lower limits
allows D/A conversion to
be executed and analog
signals to be output with
these values as full scale.
Offset/gain adjustment Supported
Direct conversion D/A conversion is
performed and the output
value is refreshed when
the ANALOG OUTPUT
DIRECT CONVERSION
instruction (AODC) is
executed. This instruction
is supported by the CJ2H-
CPU[][](-EIP) CPU Units
with unit version 1.1 or
later, and CJ2M-CPU[][].
CJ1, NJ501, and CP1H
CPU Units and NSJ
Controllers do not support
direct conversion.