Low cost Danfoss 5.5kw vfd FC360 series 134F2978 FC360H5K5T4E20H2BXC frequency inverter

Short Description:

FC-360H5K5T4E20H2BXCDXXSXXXXAXBX

VLT® AutomationDrive FC 360
High Overload, 5.5 KW / 7.5 HP, (T4) 380-480VAC (Three phased),
IP20 / Chassis, RFI Class A2,
(B) Brake Chopper, Standard Control Card
(C) Coated PCB,

Model code:FC-360H5K5T4E20H2BXCDXXSXXXXAXBX

Danfoss VLT® AutomationDrive FC 360 is dedicated to industry applications, like pumps & fans, conveyors, extruders, draw benches and
etc, covering power range from 0.37 to 75kW, 380-480V three phase.
With a wide range of powerful standard and optional features, user-friendly design of HMI and application selections, high reliabili
ty against harsh environment, the VLT® AutomationDrive FC 360 provides high performance and versatile functions at the lowest overal
l cost of ownership, making it perfect match for OEM customers.

Note: Built-in DC choke for whole power range. Built-in braking chopper up to 22kW. LCP Displays are external options.


We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on

Product Detail

Product Tags

Spec Detail

Item

Specifications

Gross weight 5.0kg
Volume 16.53 l
EAN 5710107427338
Serier FC 360
Nennleistung 5.5 KW / 7.5 HP
Typecode FC-360H5K5T4E20H2BXC
Typecode (Teil 2) DXXSXXXXAXBX
Phase 3
Mains Voltage 380v...480v
Control Card Standard Control Card
Display No Display (No Blind Cover)
Enclosure IP20 / Chassis
RFI Filter RFI Class A2
Order Number 134F2978

industrial_compressor

Match capacity to heat load – and save energy

One of the largest cost factors in the industrial refrigeration system lifecycle is energy. In many refrigeration applications, capacity exceeds heat load due to seasonal variations, product loading, occupancy variations, and electrical appliances that cause power loss. Modern, dedicated AC drives, such as Danfoss Drives’ range of VLT® drives, provide the ideal means to continually adjust the equipment capacity to the actual heat load and process needs. The benefits are significantly lower energy consumption and lower operation and maintenance costs. 

Intelligent compressor and condenser/evaporator fan control are essential in any optimized refrigeration system. You can typically achieve 10–25% savings on energy consumption by applying Danfoss AC drives to optimize the capacity control of refrigeration compressors, condensers and evaporators. By creating stability while balancing the capacity to the actual load, the system-wide coefficient of performance (COP) improves providing significant energy savings.

Screw compressors controlled by an AC drive typically use 15% less energy than traditional screw compressors with slide valve control only. Optimized start/stop cycles reduce wear and tear on the compressor.

Drive-controlled reciprocating and scroll compressors have higher COP at part loads. VLT® drives are particularly suitable for controlling scroll compressors.

Cascade control optimizes energy savings and reduces lifecycle costs

Cascade configuration produces the optimal interaction between an application and an AC drive under partial loading. The base load is handled by a single application, such as a compressor, controlled by a drive. When heat load rises, the drive starts up additional compressors one at a time. This ensures the applications work at their optimum efficiency point, and the drive maintains maximum energy efficiency throughout the system.

Well-planned cascade control also ensures minimal wear on the individual applications. By rotating mains-powered compressors, for example, maintenance managers can ensure each ends up with a similar number of operating hours and an equal wear level. This increases the lifetime of the applications and extends service intervals reducing lifecycle costs.

Danfoss Drives’ advanced Multi-zone pack controller ensures effective cascading and control of up to six compressor packs. This minimizes energy consumption, avoids too frequent staging and de-staging, stabilizes pressures and temperatures, and reduces compressor wear and tear. Similarly, the Pump Cascade Controller distributes running hours evenly across all pumps to keep wear and tear on individual pumps to a minimum.

Fast commissioning

Commissioning is fast and easy utilizing the Danfoss Drives display panel that uses common refrigeration terms rather than computer language. The wizard guides the user through the necessary settings. Ease of programming makes installers and service technicians more comfortable and confident, makes their jobs easier and quicker, reduces human errors and improves employee productivity.


  • Previous:
  • Next:

  • RELATED PRODUCTS