We're one of the most professional FA One-stop suppliers in China.Our main products including servo motor, planetary gearbox, inverter and PLC, HMI.Brands including Panasonic, Mitsubishi, Yaskawa, Delta, TECO, Sanyo Denki ,Scheider, Siemens , Omron and etc.; Shipping time: Within 3-5 working days after getting the payment. Payment way: T/T, L/C, PayPal, West Union, Alipay, Wechat and so on
| Item Model | E2K-X4ME@, E2K-X4MF@, E2K-X4MY@ | E2K-X8ME@, E2K-X8MF@, E2K-X8MY@ | E2K-X15ME@, E2K-X15MF@, E2K-X15MY@ | 
| Sensing distance | 4mm ±10% | 8 mm ±10% | 15 mm ±10% | 
| Set distance *1 | 0 to 2.8 mm | 0 to 5.6 mm | 0 to 10 mm | 
| Differential travel | 4% to 20% of sensing distance | ||
| Detectable object | Conductors and dielectrics | ||
| Standard sensing object | Grounded metal plate: 50 ´ 50 ´ 1 mm | ||
| Response frequency | E and F Models: 100 Hz, Y Models: 10 Hz | ||
| Power supply voltage*2 (operating voltage range) | E and F Models: 12 to 24 VDC (10 to 30 VDC)Y Models: 100 to 220 VAC (90 to 250 VAC) | ||
| Current consumption | E and F Models: 15 mA max. | ||
| Leakage current | Y Models: 2.2 mA max. (Refer to page 4.) | ||
| Load current | E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA | ||
| Residual voltage | E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on page 4. | ||
| Indicators | E and F Models: Detection indicator (red), Y Models: Operation indicator (red) | ||
| Operation mode (with sensing object approaching) | E1, F1, and Y1 Models: NOE2, F2, and Y2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on page 4 for details. | ||
| Protection circuits | E and F Models: Reverse polarity protection, Surge suppressor, load short-circuit protection, output reverse polar- ity protection, Y Models: Surge suppressor | ||
| Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | Operating/Storage: -10 to 55°C (with no icing or condensation) | |
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||
| Temperature influence | ±20% max. of sensing distance at 23°C in the operating temperature range | ||
| Voltage influence | E and F Models: ±2% max. of sensing distance at rated voltage at rated voltage ±20% Y Models: ±2% max. of sensing distance at rated voltage at rated voltage ±10% | ||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||
| Dielectric strength | E and F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case | ||
| Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||
| Shock resistance | Destruction: 500 m/s2 3 times each in X, Y, and Z directions | ||
| Degree of protection | IP66 (IEC), in-house standards: oil-resistant | ||
| Connection method | Pre-wired Models (Standard cable length: 2 m) | ||
| Weight (packed state) | Approx. 65 g | Approx. 145 g | Approx. 205 g | 




 
                         
                         
                         
                                    
                            